page 5
the coastal
series controls
PROGRAMMABLE FILTER TIMES
F1: 45 minutes F2: 2 hours F4: 4 hours F6: 6 hours
• To adjust the filter time: First press the TEMP SET pad, then press the ZONE 1 JETS.
• The LCD display will show either F1 (45 minutes), F2 (two hours), F4 (four
hours), or F6 (six hours). Press the TEMP SET pad to scroll through the selec-
tions and then press the ZONE 1 JETS pad to enter.
• The display will now show either 2C (two filter cycles per day), 1d (one cycle per
day that will start one minute after power up) or 1n (one cycle per day that starts
12 hours after power up). Press the TEMP SET pad to scroll through the
selections and press ZONE 1 JETS pad to enter.
• The display will now show either 4H (four hour cycle), 3H (three hour cycle), 2H
(two hour cycle), 1H (one hour cycle) or 0H (smart cycle off). Press the TEMP
SET pad to scroll through the selections and then press the ZONE 1 JETS pad to
set and exit the programming mode.
Factory default settings for the above selections: Filtration time F1 (45 minutes);
Filter cycles 2C (two times per day); Cleanup cycle “Smart Logic” 4H (four hours)
NOTE: In event of a power outage, all settings will be retained.
The filter cycle will begin six minutes after the spa is energized. If you select two cycles
per 24 hours, the second cycle will begin 12 hours after the first cycle. The primary
pump will run on high-speed for five minutes, then low-speed for the cycle’s duration.
CONSTANT CLEAN
™
FILTRATION WITH SMART LOGIC
Constant Clean
™
Filtration
Your spa is automatically preset to filter itself using the jet pump on low-speed for
two hours twice in a 24 hour period. The first filter cycle will begin six minutes after
the spa is energized. The second filter cycle will begin 12 hours after the first cycle. See
PROGRAM FILTER to adjust cycles.
Smart Logic
This feature ensures that the spa water will be properly filtered after each spa use.
30 minutes after the spa light or jet pump has been deactivated, the pump runs on
high-speed for five minutes, then on low-speed to filter the water for one hour. See
PROGRAM FILTER to adjust cycles.
Heat Demand Operation
In addition to those situations mentioned above, the pump will circulate on low-
speed whenever the thermostat calls for heat.
SOLID-STATE Q
3
OZONATOR
The Q
3
Ozonator will function whenever the primary pump is running on low-speed.
HEAT MODE
The spa’s heat mode can be adjusted to one of three different settings.
• Standard Mode: The spa water will heat to the temperature as set at the Bather’s
panel. In this mode the filtration pump will turn on for one minute every half-hour
and “poll” or check the water. If heat is needed the unit will heat to the set
temperature. LCD display will steadily read actual temperature in this mode.
• Economy Mode: In this mode the spa will only heat to the set temperature during a
programmed filter cycle. LCD display will alternately flash
when spa is up to set temperature. LCD will steadily display
below set temperature.
“Ec” with actual temperature
“Ec” when spa is
Comentarios a estos manuales